Stress analysis of a bulk-filled class-V chemical-cured dental composite restoration

Author(s):  
T. R. Katona ◽  
M. M. Winkler ◽  
J. Huang
2011 ◽  
Vol 30 (4) ◽  
pp. 517-522 ◽  
Author(s):  
Pisol SENAWONGSE ◽  
Pong PONGPRUEKSA ◽  
Choltacha HARNIRATTISAI ◽  
Yasunori SUMI ◽  
Masayuki OTSUKI ◽  
...  

1994 ◽  
Vol 73 (8) ◽  
pp. 1470-1477 ◽  
Author(s):  
T.R. Katona ◽  
M.M. Winkler

Clinical failures are often associated with the polymerization shrinkage of resin composite restorative materials. These problems include tooth sensitivity and fracture, marginal leakage, loss of the restoration, and recurrent decay. Our goal was to examine transient composite distortions and interface stresses as a bulk-filled light-cured composite polymerized in a Class V restoration. The analysis was based on a finite element model. The curing of the restoration was divided into 4 steps: approximately 1/30, 1/4, 1/2, and full depth (1/1) of cure. Since the actual curing pattern is not known, calculations were performed for three hypothetical (flat, convex, and concave) polymerization front shapes. The calculations showed that the assumed shape was a critical factor in determining cured surface deformations. For example, the initial cure depth (1/30) resulted in a surface bulge if the polymerization front was presumed convex, while the concave front resulted in a large intrusion. By the time that about 1/2 the depth of the restoration was cured, the differences were essentially gone. The final surface outline was intruded. Interface stresses in the curing restoration were qualitatively similar regardless of the assumed polymerization shape. As with surface distortions, the stresses changed with curing depth. It was concluded that (1) transient events during polymerization are possible contributors to clinical complications, and (2) more must be known about the polymerization pattern.


2010 ◽  
Vol 11 (5) ◽  
pp. 25-32 ◽  
Author(s):  
Hamideh Ameri ◽  
Marjaneh Ghavamnasiri ◽  
Ehsan Abdoli

Abstract Aim This study evaluated the influence of mechanical loading and thermocycling on microleakage of class V resin-based composite restorations with and without enamel bevel. Methods and Materials Sixty class V cavity preparations measuring 3.0 mm wide (mesiogingivally) x 2.0 mm high (occluso-gingivally) x 1.5 mm deep with the occlusal margin in enamel and the gingival margin in cementum were prepared on the buccal surfaces of human premolars using a #12 diamond round bur (Drendel & Zweiling Diamant GmbH, Lemgo, Germany) in a high-speed, water-cooled handpiece. The specimens were then divided into two groups of 30 specimens each, based on the type of enamel cavosurface margin configuration as beveled or nonbeveled (butt joint). After restoring the preparations with a flowable resin-based composite (Tetric Flow, Ivoclar Vivadent-AG, Schaan, Liechtenstein) and finishing and polishing with sequential discs (Sof-Lex Pop-on, 3M-ESPE, St. Paul, MN, USA), the teeth were stored at 37°C and 100 percent humidity. Twenty-four hours later, half of the specimens in each group (nonbeveled “N” or beveled “B”) were exposed to a cycling loading for 250,000 cycles to simulate occlusal loading and assigned to two subgroups (NL+ or BL+), while the remainder of the specimens in each group were only maintained in a 100-percent-humidity environment, without any cyclical loading, until tested (NL– or BL–). The specimens were sealed with sticky wax (Kemdent, Associated Dental Products, Swindon, UK) and nail polish. The apical foramen of each tooth was sealed with sticky wax and the rest of the tooth was covered with nail varnish, except for an area within 1.0 mm around the composite restoration. To detect marginal leakage, all of the samples were stored in a 0.5 percent basic fuchsine solution for 24 hours. The specimens were then sectioned longitudinally using a low-speed diamond blade (IsoMet, Buehler Ltd., Lake Bluff, IL, USA), machined, and evaluated under 25X magnification using a stereomicroscope (M9, Wild Heerbrugg, Switzerland). The specimens were scored on a scale from 1 to 4 on the degree of dye penetration. The qualitative data were analyzed by the Mann- Whitney U test at a 5 percent significance level (p<0.05). The null hypothesis of this study was that there is no difference in microleakage between beveled and nonbeveled class V buccal preparations in premolar teeth restored with resinbased composite and subjected to simulated occlusal loading and thermocycling. Results In each group the gingival margin showed significantly more microleakage than the enamel margin (p<0.05). Load cycling did not result in an increase in microleakage in nonbeveled (p=0.259) or in beveled (p=0.053) occlusal margins. However, the gingival margins showed a statistically significant difference in microleakage after load cycling whether in cavities with enamel occlusal bevel (p=0.004) or in groups without a bevel. This means the enamel margin configuration of the enamel occlusal margin had no effect on decreasing microleakage in the gingival aspect of class V composite restorations. In general, the nonbeveled preparations in this study had significantly less microleakage than the bevel specimens whether they were loaded occlusally or not (p=0.001). Clinical Significance Within the limitations of this in vitro study, no benefit was derived from placing an enamel cavosurface bevel on the occlusal margin of a standardized class V composite restoration located at the cementoenamel junction. The most important consideration is to prevent microleakage along the gingival margin regardless of whether the occlusal enamel margin is beveled. Citation Ameri H, Ghavamnasiri M, Abdoli E. Effects of load cycling on the microleakage of beveled and nonbeveled occlusal margins in class V resin-based composite restorations. J Contemp Dent Pract [Internet]. 2010 October; 11(5):025- 032. Available from: http://www.thejcdp.com/ journal/view/volume11-issue5-ghavamnasiri


Author(s):  
Anshu Milind Chandurkar ◽  
Sandeep S Metgud ◽  
Shaikh S Yakub ◽  
Vaishali J Kalburge

ABSTRACT Aims The purpose of this study was to evaluate the effect of light intensity and curing cycle of quartz tungsten halogen (QTH) and plasma arc curing (PAC) lights on the microleakage of class V composite restorations. Materials and methods A total of 60 freshly extracted human maxillary premolars were used for this study. Standardized class V cavities were prepared and restored with microhybrid resin composite. According to the curing protocol, the teeth were then divided into three groups (n = 20): QTH curing (standard and soft start mode) and PAC high intensity irradiation.   The microleakage was evaluated by immersion of the samples in 50% silver nitrate solution. The samples were then sectioned, evaluated under a stereomicroscope and scored for microleakage. Statistical analysis used Dye leakage scores were obtained, and analysis was done using Student's t-test. Results Light curing with QTH light in the soft start mode, showed the least leakage in the composite restoration, which was highly significant when compared with the other groups (p < 0.01). Light curing with QTH light in the standard mode, showed moderate microleakage, which was statistically significant (p < 0.05), when compared with the PAC high intensity curing. Curing with PAC light in high intensity mode resulted in severe microleakage along the cavity margins. Conclusion Within the limitations of the study, it may be concluded that: 1. The high intensity PAC light resulted in maximum leakage, when compared to the other groups in the study. 2. The soft start polymerization mode offers a distinctive advantage over the standard curing protocol, in terms of microleakage, for the QTH curing lights. Clinical significance In the clinical scenario, soft start curing regimen offers a distinctive advantage over the conventional mode of the QTH curing and the high intensity rapid curing offered by the PAC light. How to cite this article Chandurkar AM, Metgud SS, Yakub SS, Kalburge VJ. Evaluation of Microleakage in Class V Composite Restoration using Different Techniques of Polymerization. Int J Prosthodont Restor Dent 2012;2(1): 10-15.


Nanomaterials ◽  
2020 ◽  
Vol 10 (7) ◽  
pp. 1339
Author(s):  
Ksenia Babina ◽  
Maria Polyakova ◽  
Inna Sokhova ◽  
Vladlena Doroshina ◽  
Marianna Arakelyan ◽  
...  

The purpose of this study was to investigate the effect of final surface treatment and dental composite type on the roughness of the composite surface, composite/enamel interface, and composite/cementum interface, as well as on the polishing time. Class V cavities prepared in extracted teeth (n = 126) were restored using one of the three nanohybrid composites with different filler sizes. The specimens were randomly assigned to three different finishing and polishing sequences. The roughness (Ra) of the investigated surfaces was measured using the contact profilometer. The time required to achieve visible gloss was documented. The data were analyzed using ANOVA with Tukey’s post hoc test (p < 0.05). There was no significant influence of the composite type on the restoration surface roughness (p = 0.088), while the polishing method had a significant impact (p < 0.001). The Ra of the composites ranged between 0.08 µm and 0.29 µm, with the lowest values (0.09 µm ± 0.05 µm) found in the aluminum oxide disc group (p < 0.001). The time to achieve a visible composite gloss was influenced by the polishing method, composite type, and interactions between these factors (p < 0.001). The interface roughness was significantly greater than that of the composite surface (p < 0.001), and depended on the composite type and polishing system employed.


2017 ◽  
Vol 78 ◽  
pp. 333-340 ◽  
Author(s):  
Danfeng Cao ◽  
Yingchao Zhang ◽  
Yao Li ◽  
Xiaoyu Shi ◽  
Haihuan Gong ◽  
...  

2020 ◽  
Vol 32 (1) ◽  
pp. 9-15
Author(s):  
Bahar J Selivany ◽  
Muhand A Khadim ◽  
Dara H Saeed ◽  
Abdulhaq A Suliman

Background: Vibration decreases the viscosity of composite, making it flow and readily fit the walls of the cavity. This study is initiated to see how this improved adaptation of the composite resin to the cavity walls will affect microleakage using different curing modes Materials and methods: Standard Class V cavities were prepared on the buccal surface of sixty extracted premolars. Teeth were randomly assigned into two groups (n=30) according to the composite condensation (vibration and conventional) technique, then subdivided into three subgroups (n=10) according to light curing modes (LED-Ramp, LED-Fast and Halogen Continuous modes). Cavities were etched and bonded with Single Bond Universal then restored with Filtek® Z350 (3M ESPE, USA). In the vibration group, condensation was done using CompothixoTM (Kerr, Switzerland). In the conventional group, condensation was done with hand plugger. Curing modes for all groups were LED-Ramp, LED-Fast and halogen continuous modes, respectively. Samples stored in distilled water at 37°C for seven days, and painted completely with two layers of nail varnish with only 1 mm around the composite restoration left. Samples were thermocycled, immersed in 2% methylene blue solution for 3 hours, and sectioned longitudinally. Dye penetration was assessed under a stereomicroscope. Data were analyzed by Kruskal-Wallis and Mann-Whitney U tests with p <0.05 considered significant. Results: Vibration group showed less microleakage (P=0.028). In the conventional group there were no differences by using different curing modes (P=0.277). In the vibration group no differences were found between LED-Ramp and LED-Fast mode (P=0.989). However, there were significant differences between LED-Fast and halogen (P=0.05) and between LED-Ramp and halogen group (P=0.001). Microleakage scores of all cervical walls were higher than the occlusal walls (P=0.001). Occlusal walls leakage for conventional and vibration groups were not different (P=0.475), while there were significant differences between them at cervical walls (P=0.001). Conclusion: Vibration with LED-Ramp curing mode may decrease marginal leakage of composite restoration placed in Standard Class V tooth preparations. Keywords: Composite resin, Vibration, Condensation, Compothixo, Microleakage,


Sign in / Sign up

Export Citation Format

Share Document